Rki-instruments 65-2484RK User Manual

Browse online or download User Manual for Sensors Rki-instruments 65-2484RK. RKI Instruments 65-2484RK User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Operator’s Manual

RKI Instruments, Inc.www.rkiinstruments.com65-2484RKMulti Point DetectorOperator’s ManualPart Number: 71-0252RKRevision: 0Released: 7/18/14

Page 2

6 • 65-2484RK Multi Point DetectorOxygen DetectorThe detector consists of the oxygen sensor, the detector housing body, detector housing cap, and ca

Page 3 - Product Warranty

65-2484RK Multi Point Detector • 7H2S DetectorThe detector consists of the detector housing body, detector housing cap, cap gasket, rubber boot, spac

Page 4 - Table of Contents

8 • 65-2484RK Multi Point DetectorCO DetectorThe detector consists of the CO sensor, charcoal filter with rubber boot, detector housing body, detect

Page 5 - Specifications

65-2484RK Multi Point Detector • 9ESM-01 DetectorThe ESM-01 detector consists of the detector housing body, detector housing cap, splashguard, cap ga

Page 6

10 • 65-2484RK Multi Point DetectorJunction BoxesUse the junction boxes to install the multi-point detector at a mounting site that is remote from t

Page 7

65-2484RK Multi Point Detector • 11Figure 7: Outline & Mounting Dimensions for Versions with Catalytic LEL Detector(65-2484RK-0X, 65-2484RK-2X, 6

Page 8 - Description

12 • 65-2484RK Multi Point DetectorFigure 8: Outline & Mounting Dimensions for Versions with IR LEL Detector(65-2484RK-1X, 65-2484RK-3X, 65-2484

Page 9 - IR LEL Detector

65-2484RK Multi Point Detector • 13Wiring the Multi-Point Detector to a ControllerWARNING: Always verify that the power source is OFF before you make

Page 10 - Plug-in Oxygen Sensor

14 • 65-2484RK Multi Point DetectorFigure 9: Wiring for Catalytic LEL/O2/H2S/ESM-01 Versions(65-2484RK-0X)OXYGEN DETECTORCONTROLLER TERMINALSWHITEGR

Page 11 - Rubber Boot and Spacer

65-2484RK Multi Point Detector • 15Figure 10: Wiring for Catalytic LEL/O2/CO/ESM-01 Versions(65-2484RK-4X)OXYGEN DETECTORCONTROLLER TERMINALSWHITEGRE

Page 12 - Charcoal Filter

65-2484RK Multi Point DetectorWARNINGRead and understand this instruction manual before operating detector. Improper use of the detector could result

Page 13 - Conduit Seal

16 • 65-2484RK Multi Point DetectorFigure 11: Wiring for LEL/CO/H2S/ESM-01 Versions(65-2484RK-2X)CONTROLLER TERMINALSAsH3 brownCl2 yellowHCN whiteNH

Page 14 - Installation

65-2484RK Multi Point Detector • 17Figure 12: Wiring for IR LEL/O2/H2S/ESM-01 Versions(65-2484RK-1X)ESM-01(+) SEETABLEBLACKGas Type + W ireAsH3 brown

Page 15

18 • 65-2484RK Multi Point DetectorFigure 13: Wiring for IR LEL/O2/CO/ESM-01 Versions(65-2484RK-5X)ESM-01(+) SEETABLEBLACKGas Type + W ireAsH3 brown

Page 16

65-2484RK Multi Point Detector • 19Figure 14: Wiring for IR LEL/CO/H2S/ESM-01 Versions(65-2484RK-3X)BLKREDBLKBLKREDESM-01BLACK(+) SEETABLEAsH3 brownC

Page 17

20 • 65-2484RK Multi Point Detector9. Connect the cable’s drain wire to an available chassis ground at the controller. RKI controllers typically hav

Page 18 - (65-2484RK-0X)

65-2484RK Multi Point Detector • 21MaintenanceThis section describes maintenance procedures. It includes preventive maintenance, troubleshooting, and

Page 19 - (65-2484RK-4X)

22 • 65-2484RK Multi Point DetectorNOTE: Ensure that you are using an appropriate calibration cylinder for the channel you are testing.5. Use the ca

Page 20 - (65-2484RK-2X)

65-2484RK Multi Point Detector • 23TroubleshootingThe troubleshooting guide describes symptoms, probable causes, and recommended action for problems

Page 21 - Gas TypeTable

24 • 65-2484RK Multi Point DetectorReplacing Components of the Multi-Point DetectorThis section includes maintenance procedures for the LEL detector

Page 22

65-2484RK Multi Point Detector • 25detector housing body.7. Turn on or plug in power to the controller.8. Turn on the controller and place into norma

Page 23

65-2484RK Multi Point Detector Product WarrantyRKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in materials, wo

Page 24 - Start Up

26 • 65-2484RK Multi Point Detector3. Unscrew the detector housing cap from the detector housing body. Make sure not to lose the cap gasket.4. Unplu

Page 25 - Maintenance

65-2484RK Multi Point Detector • 27CO DetectorThis section includes a procedure to replace the plug-in sensor, one to replace the charcoal filter, an

Page 26 - Performing the response test

28 • 65-2484RK Multi Point DetectorReplacing the CO DetectorNOTE: In most cases, it is only necessary to replace the CO sensor.1. Turn off the contr

Page 27 - Troubleshooting

65-2484RK Multi Point Detector • 29WARNING: You must replace the plug-in sensor with the same type of sensor that is installed. A detector cannot be

Page 28

30 • 65-2484RK Multi Point DetectorCalibration FrequencyAlthough there is no particular calibration frequency that is correct for all applications,

Page 29 - S Sensor

65-2484RK Multi Point Detector • 31for instructions to enter the calibration program.NOTE: RKI controllers have a minimum hold feature for zero adjus

Page 30 - S Detector

32 • 65-2484RK Multi Point Detector• 0 ppm for H2S or CO4. Store the components of the calibration kit in a safe and convenient place.Calibration, O

Page 31 - Replacing the Charcoal Filter

65-2484RK Multi Point Detector • 336. Unscrew the regulator from the zero air calibration cylinder. Leave the sample tubing connected to the regulato

Page 32 - Replacing the CO Detector

34 • 65-2484RK Multi Point DetectorWARNING: Not using the recommended 81-1138RK-XX calibration cup, recommended sample flowrate, and specified flow

Page 33 - Replacing the ESM-01 Detector

65-2484RK Multi Point Detector • 35NOTE: Depending on the size of your zero air cylinder, it is possible that you will have a different regulator for

Page 34 - S, and CO Detectors

65-2484RK Multi Point DetectorTable of ContentsOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35 - Returning to Normal Operation

36 • 65-2484RK Multi Point DetectorParts ListTable 5 lists replacement parts and accessories for the multi-point detector.Table 4: Parts ListPart Nu

Page 36 - Detector

65-2484RK Multi Point Detector • 3765-2484RK-16 Multi-point detector assembly, LEL (IR CH4)/O2/H2S/SO265-2484RK-21 Multi-point detector assembly, LEL

Page 37

38 • 65-2484RK Multi Point Detector81-0004RK-03 Calibration cylinder, 50% LEL propane in air, 103 liter steel81-0007RK Calibration cylinder, 15% LEL

Page 38 - Preparing for Calibration

65-2484RK Multi Point Detector • 3981-0196RK-02 Calibration cylinder, 10 ppm HCN in nitrogen, 58 liter aluminum81-0196RK-04 Calibration cylinder, 10

Page 39

65-2484RK Multi Point Detector • 1OverviewThis manual describes the 65-2484RK multi point direct connect detector. This manual also describes how to

Page 40 - Parts List

2 • 65-2484RK Multi Point Detector Table 1: SpecificationsTarget Gas 65-2484RK-01: LEL/O2/H2S/AsH3, methane calibration standard for LEL65-2484RK-02

Page 41

65-2484RK Multi Point Detector • 3NOTE: The following symbol on the detector label is a caution to the user to refer to this documentation for instal

Page 42

4 • 65-2484RK Multi Point DetectorDescriptionThis section describes the multi-point detector. It consists of the detectors, the terminal strips, the

Page 43

65-2484RK Multi Point Detector • 561-0190RK IR LEL DetectorFigure 2: 61-0190RK IR LEL Detector Component LocationThe infrared LEL detector is made up

Comments to this Manuals