55 Using Setup Mode GX-2003 Operator’s Manual
4. Press and release the POWER ENTER button to save the new
alarm point and move to the next set alarm screen.
5. Repeat step 3 and 4 to update additional alarms while in the
desired set alarm screen.
6. Press and release the POWER/ENTER button repeatedly until you
return to the screen that displays all the detection channels.
7. Repeat steps 2 through 6 until all desired alarms are updated.
8. To exit ALARM POINTS, use the (SHIFT) button to move the
cursor to the last menu item on the screen, then press and release
the (SHIFT) button again. The ESCAPE message displays.
9. Press and release the POWER ENTER button to save the settings
and return to the main menu.
Updating the Lunch Break Setting
With LUNCH BREAK set to OFF (factory setting), the GX-2003
automatically starts new TWA and PEAK reading collection and
resets the time in operation at start up.
With LUNCH BREAK set to ON, the Resume Datalog Screen displays
during start up. From this screen, you can choose to continue
accumulating TWA and PEAK readings and the time in operation
from the last time the GX-2003 was used or start collecting new
readings.
1. From the main menu, place the cursor next to the LUNCH BREAK
menu item. Press and release the POWER ENTER button.
2. Use the AIR or (SHIFT) button to display the desired setting.
3. Press and release the POWER/ENTER button to save the setting
and return to the main menu.
LUNCH BREAK
OFF
21:09