STAND ALONE CALIBRATION STATION
SM-2000 Series
Gas Detection For Life
World Leader In Gas Detection & Sensor Technology
www.rkiinstruments.com
RKI Instruments, Inc. 33248 Central Ave. Union City, CA 94587 Phone (800) 754-5165 (510) 441-5656 Fax (510) 441-5650
Features
• Stand alone system, no PC needed for operation
• Calibrate, bump test, charge, and archive data
• Software manages records by serial #, user ID,
or station ID
• Each station is equipped with configuration control
and status indicators
• User adjustable test times and tolerances
• Automatic quick charge of instrument in 90 minutes
or less
• Alkaline recognition will not attempt to charge
alkaline batteries (SM-2003U)
• Exhaust line connection for test gas venting
• Records are stored as a tab delineated text file
(.txt format can be imported into a spreadsheet)
• Software is Windows Vista, and XP compatible
Operates on any Pentium II or higher PC
USB port for downloading data to a USB flash drive
USB flash drive included
Models SM-2009U, SM-2001U & SM-2003U
The SM-2000 single module calibration station for
the GX-2009, GX-2003, and GX-2001 portable gas
monitors is a stand alone station that can calibrate,
bump test, charge, and archive data without the
need of a computer to operate. The module has 4
operating modes, which include bump test only, %
volume methane bump/calibration (for the GX-2003),
calibration only, and bump with automatic calibration
(if the bump test fails). The SM-2000 modules are
capable of storing up to 200 bump test or calibration
records. To download the data each module includes
a 64 MB USB flash drive. Also included is a software
package to import the data from the USB drive and
manage records by serial #, user ID, or station ID.
Each module has user adjustable test times and
tolerances to meet specific testing requirements.
The charger within the module quick charges battery
packs within 90 minutes and will recognize alkaline
batteries. The Calibration Station power requirements
are 115/230 VAC, 50/60Hz.
PO25 0812/2000
Calibration Stations
81-SM2009U
GX-2009 Ca brat on stat on, nc udes power cord, USB
f ash dr ve, and software
81-SM2001U
GX-2001 Ca brat on stat on, nc udes power cord, USB
f ash dr ve, and software
81-SM2003U
GX-2003 Ca brat on stat on, nc udes power cord, USB
f ash dr ve, and software
81-SM2001UC
GX-2001 Ca brat on stat on, nc udes power cord, USB
f ash dr ve, and software (eva uated to Canad an e ectr ca
code safety standard)
81-SM2003UC
GX-2003 Ca brat on stat on, nc udes power cord, USB
f ash dr ve, and software (eva uated to Canad an e ectr ca
code safety standard)
Calibration Gases & Regulators
81-0154RK-02 LEL CH4/O2/CO/H2S, 58L
81-0155RK-02 LEL Hexane/O2/CO/H2S, 58L
81-0090RK-03 LEL CH4/O2/CO, 103L
81-0089RK-03 LEL Hexane/O2/CO, 103L
81-0016RK-05 100% Vo . CH4, 58L
81-0151RK-02 H2S/N2, 58L
81-0078RK-03 100% N2, 103L
81-1054RK Demand F ow Regu ator
06-1248RK-03 Ca brat on Tub ng, Po yurethane (3/16” x 5/16” x 3 )